Table 38 – HP XP Continuous Access Software User Manual

Page 192

Advertising
background image

To create the correct RAID Manager XP configuration definition file, HP recommends creating a file system

to be temporarily paired before executing the mkconf.sh command. After creating the RAID Manager XP

configuration definition file using the mkconf.sh command, you can continue using the file system in the

primary site. Alternatively, you can delete it and create a file system with the same configuration using the

same LU in

Create file systems in Continuous Access XP Journal P-VOLs

. You must delete the temporarily

created file system in the secondary site before creating a file system pair.
The following explains how to create a RAID Manager XP configuration definition file in the NAS

package in CL1 in the primary site in the sample configuration above. You must create RAID Manager XP

configuration definition files for the other three NAS packages using the previously explained procedure.

Creating a template for a RAID Manager XP configuration definition file

Table 37

shows an example of how to create a template for a RAID Manager XP configuration definition

file.

Table 37 Example of mkconf.sh execution results (for instance number 16)

$ cat /home/nasroot/horc_devfile | sudo mkconf.sh -gg VG -i 16 -a
starting HORCM inst 16
HORCM inst 16 starts successfully.
HORCM Shutdown inst 16 !!!
A CONFIG file was successfully completed.
starting HORCM inst 16
HORCM inst 16 starts successfully.
DEVICE_FILE Group PairVol PORT TARG LUN M SERIAL LDEV
/dev/sdj VG VG_000 CL1-A-1 0 17 - 62486 70
/dev/sdk VG VG_001 CL1-A-1 1 18 - 62486 18
?
?
/dev/sdt VG VG_010 CL1-A-1 0 10 - 62486 10
/dev/sdu VG VG_011 CL1-A-1 0 11 - 62486 64
/dev/sdv VG VG_012 CL1-A-1 0 12 - 62486 12
/dev/sdw VG VG_013 CL1-A-1 0 13 - 62486 66
/dev/sdx VG VG_014 CL1-A-1 0 14 - 62486 14
/dev/sdy VG VG_015 CL1-A-1 0 15 - 62486 68
/dev/sdz VG VG_016 CL1-A-1 0 16 - 62486 16
HORCM Shutdown inst 16 !!!
Please check '/home/nasroot/horcm16.conf','/home/nasroot/log16/curlog/

horcm_*.log', and
modify 'ip
_address & service'.
#

Editing the template for the RAID Manager XP configuration definition file

Table 38

lists the values specified for items included in the RAID Manager XP configuration definition

file in the NAS Blade system.

Table 38 Config. def. file settings (HORCM_MON, HORCM_CMD) & specif. vals.

in NAS Blade sys.

Section name

Item

Specified values in NAS Blade system

ip_address

Unique IP address for eth1 or eth2 in the local NAS package

HORCM_MON

service

20331 (Instance number 16) or 20332 (Instance number 17)

HORCM_CMD

dev_name

/dev/sdf

192

Continuous Access XP Journal operations with NAS Blade

Advertising