Continuous access xp journal suspension conditions – HP XP Continuous Access Software User Manual

Page 45

Advertising
background image

shared memory. When a Continuous Access XP Journal pair is suspended, tracks containing the following

journal are marked in the differential bitmap as modified (to be copied during the pairresync operation):

Journal data the primary array has created, but has not sent to the secondary array yet
After marking these primary data volume tracks as modified, the primary array discards the journal

data.

Journal data that has been sent to the secondary array, but has not been acknowledged by

the secondary array
After marking these primary data volume tracks as modified, the primary array discards the journal

data. This ensures that journal data lost during transmission to the secondary array is identified

and marked.

Journal data that has reached the secondary array, but has not been restored yet
After marking these primary data volume tracks as modified, the primary array discards the journal

data. Therefore, the secondary array can check and mark journal data that has not been restored.
The primary array does not discard journal data from the master journal volume until the primary

array receives the restored journal volumes' sequence numbers, which are included in read journal

commands from the secondary array.

Primary data volume records updated by host-requested write I/Os after the pair was suspended

Table 8

describes Continuous Access XP Journal suspension conditions and indicates which CU

detects the condition and which pairs are suspended. See

Displaying the History Operation pane

for

troubleshooting information for Continuous Access XP Journal suspension conditions.

Table 8 Continuous Access XP Journal suspension conditions

Suspension condition

Detected by

Continuous Access XP Journal pairs to

be suspended

The secondary array could not copy the

journal data successfully due to a hardware

failure or logic error.

RCU

All Continuous Access XP Journal secondary

data volumes in the journal groups, or the

affected secondary data volume

The secondary array detected a logical

error while selecting the journal data to be

restored.

RCU

All Continuous Access XP Journal secondary

data volumes in the journal group, or only

the affected secondary volume

The secondary array could not restore the

journal data due to a hardware failure,

track condition, or logical error.

RCU

All Continuous Access XP Journal secondary

data volumes in the journal groups, or the

affected secondary data volume