Table 54 General troubleshooting information for Continuous Access XP Journal

Error

Corrective action

The Command View XP management

station hangs, or Continuous Access

XP Journal operations do not function

properly.

Ensure that the problem is not caused by the management station or

Ethernet hardware or software, and restart the management station.

Restarting the Command View XP management station does not

affect Continuous Access XP Journal operations in progress.
Ensure that all Continuous Access XP Journal requirements and

restrictions are met. See

Continuous Access XP Journal operations

requirements and restrictions

.

Ensure that the primary array, secondary array, and remote copy

connections are powered on, and NVS and cache are fully

operational.
Check all entered values and parameters to ensure you entered the

correct information on the Command View XP management station

(for example, secondary array S/N, path parameters, primary

data volume IDs, and secondary data volume IDs).
Ensure you are not using Auto LUN/Performance Control Base

Monitor.

An initiator or RCP channel-enable LED

indicator (on the Command View XP

control pane) is off or flashing.

Call you HP account support representative for assistance.

Status of pairs and/or logical paths is

not displayed correctly.

Check whether you selected correct items or options in Continuous

Access XP Journal panes, such as the DKC Operation pane, Pair

Operation pane, and Display Filter pane.

A Continuous Access XP Journal error

message is displayed on the Command

View XP management station.

Remove the error cause, and retry the Continuous Access XP

Journal operation.

The status of a logical path is not

normal.

Check the path status in the DKC Status pane, and see

Table 55

.

The pair status is suspended.

Check the pair status in the Pairdisplay pane, and see

Table 56

.

Paircreate or pairresync operation

resulted in a timeout error.

If the timeout error was caused by a hardware failure, a SIM

is generated. If this occurs, call you HP account support

representative, and retry Continuous Access XP Journal operations

after the problem is solved.
If no SIM was generated, wait for 5 or 6 minutes, and check the

pair status of the pairs being created or resumed. If the pair

status changed correctly, the failed operation completed after the

timeout message was issued. If the pair status did not change as

expected, a heavy workload might have prevented the Continuous

Access XP Journal operation from completing. In this case, retry

the Continuous Access XP Journal operation when the array has

a lighter workload.
If a communications error occurs between the Command View

XP management station and the SVP, see the HP StorageWorks

Command View XP user guide for XP Disk Arrays for instructions.

There is a pinned track on a Continuous

Access XP Journal volume.

See

Pinned track recovery for Continuous Access XP Journal

volumes