CAUTION:

If you want to downgrade the DKCMAIN microprogram version to lower than 50-09-00-00/00, you

must set the Path Watch Time within the range of 1 to 59 minutes before downgrading DKCMAIN,

or set it within the range of 1 to 60 minutes after downgrading DKCMAIN. If the Path Watch Time

is outside the range of 1 to 59 minutes before you downgrade DKCMAIN, the Path Watch Time

might not be displayed after DKCMAIN is downgraded. Use the JNL Group Detail panel to check

the Path Watch Time.

NOTE:

If the DKCMAIN microprogram version lower than 50-09-00-00/00 is used and the Path Watch

Time is set to 60 minutes, the Path Watch Time will be displayed as 60 minutes even if you upgrade

DKCMAIN to version 50-09-00-00/00 or higher.

NOTE:

If you want a mirror to get split (suspended) immediately after a path gets blocked, please ask the

Support Center to set the system option mode 448 to ON and set the system option mode 449 to

OFF. For detailed information about the modes 448 and 449, see

Table 30

.

Table 30 System option modes

Mode

Description

448

ON: If SVP detects a blocked path, SVP assumes an error occurred, and immediately

splits (suspends) the mirror.
OFF: If SVP detects a blocked path and the path does not recover within the specified time

period, SVP assumes an error occurred, and splits (suspends) the mirror.

NOTE:

The mode 448 setting takes effect only when mode 449 is set to OFF.

449

ON: SVP does not detect blocked paths.
OFF: SVP detects blocked paths and monitors the time until the mirrors are split (suspended).

NOTE:

Mode 449 is OFF by default for DKCMAIN versions earlier than 50-05-03-00/00,

and is ON by default for DKCMAIN microprogram versions 50-05-03-00/00 or

later. If the DKCMAIN microprogram of your array is upgraded from earlier than

50-05-03-00/00 to 50-05-03-00/00 or later, the default value of mode 449

remains OFF.

Forward Path Watch Time: Specifies if the master journal group's Path Watch Time value is

forwarded to the restore journal group. If the Path Watch Time value is forwarded from the

master journal group to the restore journal group, the two journal groups have the same Path

Watch Time value.
• Yes: Path Watch Time value is forwarded to the restore journal group.
• No: Path Watch Time value is not forwarded to the restore journal group. No is the default.
• Blank: The current setting of Forward Path Watch Time remains unchanged.

CAUTION:

This option cannot be specified at the secondary site.
Select Yes at the primary site of the Continuous Access XP Journal pair for delta resync operations

because you must set the Path Watch Time in the secondary site to perform delta resync operations.

Use of Cache: Specifies if journal data is stored in the restore journal group in cache.