Changing options for data volume pairs – HP XP Continuous Access Software User Manual

Page 156

Advertising
background image

Other Information: Displays the following:
• Established Time: Date and time the volume pair was created.
• Updated Time: Date and time the volume pair status was last updated.

Refresh the Pair Operation tab after this window is closed: If selected, the Pair Operation pane is

updated when the Pairdisplay pane closes.

Previous: Displays the pair status information for the previous pair in the list (the pair in the

row above).

Next: Displays the pair status information for the next pair in the list (the pair in the row below).

NOTE:

• The Display Filter settings (see

Filtering information in the list on the Pair Operation pane

) can

affect how Previous or Next is recognized.

• The list displays a maximum of 1,024 rows at once. The Previous and Next buttons on the

Pairdisplay pane can only be used for the currently displayed 1,024 rows.

Refresh: Updates the pair status information.

Close: Closes the Pairdisplay pane.

Changing options for data volume pairs

Use the Change Pair Option pane to change options for a pair of data volumes.
Only the primary array's administrator can perform the following operation. The secondary array's

administrator cannot perform the following operation.

1.

Ensure that Command View XP or XP Remote Web Console is in Modify mode. For more information,

see the HP StorageWorks Command View XP user guide for XP Disk Arrays or the HP StorageWorks

XP Remote Web Console user guide for XP12000/XP10000/SVS200.

2.

Display the Pair Operation pane (see

Displaying the Pair Operation pane

).

3.

In the list, select and right-click the desired pairs.

NOTE:

You can change options only for pairs in PAIR, PSUS, PSUE, HOLD, or HLDE status. If you

select a pair in another status, you cannot continue with the subsequent steps.

4.

Select Change Pair Option. The Change Pair Option pane appears (

Figure 62

).

5.

Change pair options, and click Set.

NOTE:

If you select two or more pairs in the list, the list on the pane might display blanks for

option values. If you do not want to change the current option value for each pair, ensure

that the list displays blanks. If you select a value other than blank from the list, the selected

value is set to each of the pairs.

6.

See the Preset list in the Pair Operation pane to check the settings you made.
• To modify a setting, right-click the setting, and select Modify.
• To cancel a setting, right-click the setting, and select Cancel.

7.

Click Apply to apply the changes.

156

Performing Continuous Access XP Journal pair operations

Advertising