Properties – MagTek IntelliStripe 320 99875168 User Manual

Page 37

Advertising
background image

Section 5. Smart Card Application

PROPERTIES

Reset Values marked with * are per ISO 7816-3(1997), or EMV 4.1. Changing these properties is not advisable unless the card you are
operating is non-standard.


General Properties used by the whole application. In order for these properties to influence a card session, they must be set before the card session
begins. Once set, these property values will persist for the current connector until a device reset, or until they are changed by further property
settings.

Name ID

(Hex)

Type Length Reset

Value

Get/Set/

Save

Description

CondRpt

00

Binary

15

N/A

Get

Operation Condition Report. This property only has meaning if the most
recent request was Power Up, Exchange APDU, or Exchange TPDU.
This property gives detailed information on the operation and is most
useful if the RC in the response was either Failure or Warning. See Error
/ Warning Condition Templates section for a detailed explanation of this
property.

CardType 01

Binary

1

0x00

Get/Set

Card

Type

See Card Types in this section for values

Volts

02

Binary

1

0x03*

Get/Set

Card Voltages allowed:
0x01 = 5 volts only
0x02 = 3 volts only
0x03 = 5 and 3 volts

UART-ID

03

Binary

11

N/A

Get

ID of Smart Card UART


Microprocessor Card Setup Properties, used to control the Power Up sequence. In order for these properties to influence a card session, they must
be set before the card session begins. Once set, these property values will persist for the current connector until a device reset, or until they are
changed by further property settings.

Name ID

(Hex)

Type Length Reset

Value

Get/Set Description

Initial ETU

15

Dword

2

372*

Get/Set

Initial value for ETU, in card clocks. Used to set bit time.

Initial CWT

16

Dword

2

449*

Get/Set

Maximum time, in 2 ms units, to wait between characters during the ATR.
In EMV Mode this property is set to 472 yielding 10080 etus.

Initial BWT

18

Dword

2

6*

Get/Set

Maximum time, in 2 ms units, to wait for first character of ATR after Reset

Default EGT

19

Dword

1

0*

Get/Set

Default EGT, used if card sends no EGT info in TC1.

Default BGT

1A

Dword

1

22*

Get/Set

Default BGT, always used.

Power Up Error
Conditions
Template

1B Binary

4

(Hex)*

0F 00 00
00

Get/Set

Used to define which conditions shall be considered errors when
powering up the card. The options in this bit-map are defined in the
description of the Power Up command.

31