Tone sequence 2 property – MagTek IntelliStripe 320 99875168 User Manual

Page 75

Advertising
background image

Section 8. Buzzer Application

69

TONE SEQUENCE 2 PROPERTY

Property ID: 02 (Hex)
Property Type: Binary

Length: 20

Power Up/Reset Value: 0330 0220 0110 0000 0000 0000 0000 0000 0000 0000 (high tone for
480 ms, medium tone for 320 ms, low tone for 160 ms)

Get/Set/Save support: All

Description:

This property specifies an audible tone that may be played when the host chooses. The property
is implemented as ten sets of Tone Information Bytes (TIB) as follows:

Byte Usage

1

TIB0, designates tone
0 = Silent
1 = Low
2 = Medium
3 = High
Other values may not result in a tone

2

TIB1, duration of tone in units of 10 milliseconds (e.g. 3 = 30
milliseconds). Setting this byte to zero terminates the Tone Sequence
without processing further entries


Example Get Property Request:

Field MTYP

APPL

CMND

RC

PTYP

PID

Byte

1 2 3 4 5 6

Value

(Hex)

00 07 00 00 04 01


Example Get Property Response:

Field MTYP

APPL

CMND

RC

PTYP

PID

Byte

1 2 3 4 5 6

Value

(Hex)

40 07 00 00 04 01

PVAL

7-26

03 30 02 20 01 10 00 00 00 00 00 00 00 00 00 00 00 00 00 00