MagTek IntelliStripe 320 99875168 User Manual

Page 44

Advertising
background image

IntelliStripe 320 Command Reference

38

Current T=1
Warning Conditions
Template

92

Binary

4

N/A*

Get/Set

Used to define which conditions shall be considered warnings when
running with the T=1 protocol. See Error / Warning Condition Templates
for further discussion. See T=1 Error / Warning Conditions for specific
coding. The values are initialized from the Initial T=1 Warning Conditions
Template property.

Current Use EMV
NAD Rules

93

Boolean

1

N/A

Get/Set

TRUE indicates to validate NAD according to EMV rules. FALSE
indicates to ignore NAD received from cards. In EMV Mode this property
is TRUE. The value is initialized from the Initial Use EMV NAD Rules
property.


Note: Other Property IDs are specified in Appendix B. Memory Card Support.

Advertising