MagTek IntelliStripe 320 99875168 User Manual

Page 39

Advertising
background image

Section 5. Smart Card Application

ATR Secondary
Timeout

24

Dword

2

0*

Get/Set

If this property is zero, there is no limit on the total time an ATR takes to
complete. If this property has a non-zero value, it specifies (in 2 ms
intervals) the maximum time allowed from the start of the first byte of the
ATR to the reception of the last byte in the ATR. If this time is exceeded,
the card is deactivated and the Power Up request fails. In EMV Mode
this property is set to 939, which yields 20160 etus.

EMV Reset Rules

25

Boolean

1

FALSE*

Get/Set

If this property is TRUE, EMV Reset Rules are followed in the Power Up
sequence. If this property is FALSE, only a Cold Reset is performed. In
EMV Mode this property is TRUE. See EMV specification for details of
operation.

TC2 Minimum

26

Binary

1

0x01*

Get/Set

This property gives the minimum value allowed for TC2 in the ATR. A
lower value will cause an Error or Warning depending on the contents of
the Error and Warning Condition Templates.

TC2 Maximum

27

Binary

1

0xFF*

Get/Set

This property gives the maximum value allowed for TC2 in the ATR. A
higher value w ill cause an Error or Warning depending on the contents of
the Error and Warning Condition Templates. In EMV Mode this property
has the value 10. TC2 is used to calculate the Work Waiting Time in T=0.

TA3 Minimum

28

Binary

1

1*

Get/Set

This property gives the minimum value allowed for TA3 in the ATR. A
lower value w ill cause an Error or Warning depending on the contents of
the Error and Warning Condition Templates. In EMV Mode this property
has the value 16. TA3 gives IFSC, the maximum number of bytes in the
INF field of a T=1 message.

TA3 Maximum

29

Binary

1

254*

Get/Set

This property gives the maximum value allowed for TA3 in the ATR. A
higher value w ill cause an Error or Warning depending on the contents of
the Error and Warning Condition Templates. TA3 gives IFSC, the
maximum number of bytes in the INF field of a T=1 message.

BWI Maximum

2A

Binary

1

9*

Get/Set

This property gives the maximum value allowed for BWI in the ATR. A
higher value w ill cause an Error or Warning depending on the contents of
the Error and Warning Condition Templates. BWI is found in TB3 of the
ATR and is used to calculate the Block Wait Time (BWT) for T=1. In EMV
Mode this property is 4.

CWI Maximum

2B

Binary

1

15*

Get/Set

This property gives the maximum value allowed for CWI in the ATR. A
higher value w ill cause an Error or Warning depending on the contents of
the Error and Warning Condition Templates. CWI is found in TB3 of the
ATR and is used to calculate the Character Wait Time (CWT) for T=1. In
EMV Mode this property is 5.

33

Advertising