Section 9. Host Communications Application
81
FIXED BAUD RATE PROPERTY
Property ID: 06 (Hex)
Property Type: Dword
Power Up/Reset Value: 0a (hex) (57600 baud)
Get/Set/Save support: All
Description:
This property contains the value of the RS232 interfaces fixed baud rate. The MCP protocol
does not use this property unless its host communications applications MCP auto baud enable
property is set to false. After changing this property, the property will also need to be saved in
non-volatile memory (Save property command) and the device will need to be power cycled or
reset before the change will take affect.
Values:
Value (hex)
Baud Rate
05 9600
06 14400
07 19200
08 28800
09 38400
0A 57600
0B 115200
Example Set Property Request:
Field MTYP
APPL
CMND
RC PTYP
PID
Byte 1
2 3 4 5 6
Value
(Hex)
00
08 01 00 01 06
Field PVAL
Byte
7 - 10
Value (Hex)
0a 00 00 00 (57600 baud)
Example Set Property Response:
Field MTYP
APPL
CMND
RC
Byte 1
2 3 4
Value (Hex)
40
08
01
00