MagTek IntelliStripe 320 99875168 User Manual

Page 41

Advertising
background image

Section 5. Smart Card Application

Actual EGT

3D

Dword

1

N/A

Get

This property is the EGT value for the current session. If TC1 was
transmitted in the ATR it was calculated from TC1, otherwise it was
calculated from the Default EGT property.

Actual Class

3E

Binary

1

N/A

Get

This property gives the Class Indicator as reported by the card in the
ATR, or in the absence of a Class Indicator from the card, the default
(Class A only).

Actual Specific
Mode

3F

Boolean

1

N/A

Get

This property gives the specific mode indication as reported by the card in
the ATR, or in the absence of the Specific Mode byte (TA2), the default
value:
FALSE = Negotiable Mode (default)
TRUE = Specific Mode

ATR Map

40

Binary

67

N/A

Get

This property gives a detailed analysis of the ATR as received from the
card. For details see ATR Map Structure.


T=0 Microprocessor Card Setup Properties, used to control the T=0 protocol operations. In order for these properties to influence a card session,
they must be set before the card session begins. Once set, these property values will persist for the current connector until a device reset, or until
they are changed by further property settings.

Name ID

(Hex)

Type Length Reset

Value

Get/Set

Description

Initial T=0 Error
Conditions
Template

51 Binary

4

(Hex)*

0F 00 00
00

Get/Set

Used to define which conditions shall be considered errors when running
with the T=0 protocol. See Error / Warning Condition Templates for
further discussion. See T=0 Error / Warning Conditions for specific
coding.

Initial T=0 Warning
Conditions
Template

52 Binary

4

(Hex)

00 00 00
00

Get/Set

Used to define which conditions shall be considered warnings when
running with the T=0 protocol. See Error / Warning Condition Templates
for further discussion. See T=0 Error / Warning Conditions for specific
coding.

T=0 INS Mask

53

Binary

1

0xFE*

Get/Set

This property defines the mask that is ANDed with an INS byte returned
from the card. If the INS byte, or its inverse, matches the result, the INS
byte is considered to be a valid procedure byte. In the EMV Mode, this
property is set to 0xFF, requiring all bits to match.


T=0 Microprocessor Card Operating Properties, used to control the T=0 protocol operations. Settings of these properties only apply to the current