Rf on command, Rf off command – MagTek IntelliStripe 320 99875168 User Manual
Page 95
Section 10. OTI SCI 1000 Contactless Smart Card Application
89
RF ON Command
Command ID: 84 (Hex)
Description:
This command is used to turn the RF field ON.
Request Message Data: None
Response Message Data: None
Response Message Result Codes:
Success = 00 (Hex)
The command completed successfully.
Example Request:
Field MTYP
APPL
CMND
RC
Byte 1
2 3 4
Value (Hex)
00
0E
84
00
Example Response:
Field MTYP
APPL
CMND
RC
Byte 1
2 3 4
Value (Hex)
40
0E
84
00
RF OFF COMMAND
Command ID: 85 (Hex)
Description:
This command is used to turn the RF field OFF. When this command is accepted by the reader,
the automatic control of the RF will also be disabled
Request Message Data: None
Response Message Data: None
Response Message Result Codes:
Success = 00 (Hex)
The command completed successfully.
Example Request:
Field MTYP
APPL
CMND
RC
Byte 1
2 3 4
Value (Hex)
00
0E
85
00
Example Response:
Field MTYP
APPL
CMND
RC
Byte 1
2 3 4
Value (Hex)
40
0E
85
00