IntelliStripe 320 Command Reference

44

POWER DOWN COMMAND

Command ID: 81 (Hex)
Description:

This command is used to power down a smart card in the currently selected connector.

Request Message Data: None
Response Message Data: None
Response Message Result Codes

Code Meaning
00 Success.


Example Request:

Field MTYP

APPL

CMND

RC

Byte

1 2 3 4

Value

(Hex)

00 02 81 00


Example Response:

Field MTYP

APPL

CMND

RC

Byte

1 2 3 4

Value

(Hex)

40 02 81 00


T=0 ERROR / WARNING CONDITION TEMPLATES

Byte Bit Meaning

0

0

Timeout On Receive. This condition indicates a receive timeout.

0

1

Unrecoverable Receive Error. This condition indicates a receive error
that could not be corrected by the permitted number of parity
correction retries.

0

2

Invalid Procedure Byte received from card.

0

3

Unrecoverable Transmit Error. This condition indicates a transmit
error that could not be corrected by the permitted number of parity
correction retries.

0

4-7 Reserved for Future Use

1-3

All

Reserved for Future Use