Section 8. buzzer application, Get/set/save property commands – MagTek IntelliStripe 320 99875168 User Manual

Page 73

Advertising
background image

67

SECTION 8. BUZZER APPLICATION


Application ID: 07 (Hex)

Description:

This application deals with the buzzer.

Note

The buzzer is an optional feature intended to be used primarily
with the contact-less smartcard option. It is not installed on all
configurations.


The buzzer is used two distinct ways. First, it is used as a stand-alone application giving the host
the ability to generate tone sequences to guide users through operations on the device. Second, it
is used by the Contactless Card Application to indicate a media being read.

When it is being used by the Contactless Card Application, it is unavailable to the host.

The following table shows the available tones by name, designator, and frequency.

TONE DESIGNATOR

FREQUENCY

Silent 0

N/A

Low 1

1500

Hz

Medium 2

2000

Hz

High 3

2500

Hz



GET/SET/SAVE PROPERTY COMMANDS

Get Property Command ID: 00 (Hex)

Set Property Command ID: 01 (Hex)

Set Property Command ID: 02 (Hex)

Description:

These commands are used to get, set and save the value of application properties. Details of
these commands are described in the Generic command section of this document. The following
describes each property this application supports.

Advertising