Example notification sequence – MagTek IntelliStripe 320 99875168 User Manual
Page 94
![background image](/manuals/413742/94/background.png)
IntelliStripe 320 Command Reference
88
Example Notification Sequence
On the assumption that the Notify Contactless Magstripe Property is ON, the application
will send the message when a contactless card comes into the operating field.
Contactless Magstripe Notification message for Paypass, Visa Wave, ExpressPay and
Discover:
On a successful read:
Field MTYP
APPL
CMND
RC
Byte
1 2 3 4
Value
(Hex)
80 0E 00 00
Field DATA
Byte
5 – up to 124 (Variable Length)
Value (Hex)
DF 23 (LEN) (Track 1 Data) DF 22 (LEN)
(Track 2 Data)
Contactless Magstripe Notification message for Mifare:
On a successful read:
Field MTYP
APPL
CMND
RC
Byte
1 2 3 4
Value
(Hex)
80 0E 00 00
Field DATA
Byte
5 – up to 124 (Variable Length)
Value (Hex)
DF 0D (LEN) (UID)
Notes:
(1) DF 23 is the header for Track 1
(2) DF 22 is the header for Track 2
(3) LEN number of bytes available for Track 1 or Track 2.
(4) For Track 2 data, 2 characters are sent using one byte, the application software will have
to convert each character into two bytes.
(5) DF 0D id the header for a Mifare Card’s UID. See appendix D to read Mifare cards.