Storage guidelines, Long-term storage – Goulds Pumps IC - IOM User Manual

Page 12

Advertising
background image

Lifting the pump

Hoist the pump using a suitable sling under solid points such as the casing, flanges, or frame.

Storage guidelines

Long-term storage

If the pump is stored for more than 6 months, these requirements apply:

• Store in a covered and dry location.
• Store the unit free from heat, dirt, and vibrations.
• Rotate the shaft by hand several times at least every three months.

Treat bearing and machined surfaces so that they are well preserved. Refer to the drive unit and coupling
manufacturers for their long-term storage procedures.
For questions about possible long-term storage treatment services, please contact your local ITT sales
representative.

Transportation and Storage

10

Model IC, ICI, ICH, ICIH Installation, Operation, and Maintenance Manual

Advertising