Sizes
ØDN Forces in lbf (N)
Torques in ft-lb (Nm)
Fx
Fy
Fz
ΣF
Mx
My
Mz
ΣM
40-25-200
25
119 (530) 110 (490)
135 (600)
207 (920)
465 (630)
310 (420)
361 (490)
679 (920)
40-25-250
25
119 (530) 110 (490)
135 (600)
207 (920)
465 (630)
310 (420)
361 (490)
679 (920)
50-32-160
32
142 (630) 135 (600)
166 (740)
261 (1,160) 568 (770)
391 (530)
443 (600)
826 (1,120)
50-32-200
32
142 (630) 135 (600)
166 (740)
261 (1,160) 568 (770)
391 (530)
443 (600)
826 (1,120)
50-32-250
32
142 (630) 135 (600)
166 (740)
261 (1,160) 568 (770)
391 (530)
443 (600)
826 (1,120)
50-32-315
32
142 (630) 135 (600)
166 (740)
261 (1,160) 568 (770)
391 (530)
443 (600)
826 (1,120)
65-40-160
40
173 (770) 157 (700)
198 (880)
308 (1,370) 664 (900)
465 (630)
546 (740)
981 (1,330)
65-40-200
40
173 (770) 157 (700)
198 (880)
308 (1,370) 664 (900)
465 (630)
546 (740)
981 (1,330)
65-40-250
40
173 (770) 157 (700)
198 (880)
308 (1,370) 664 (900)
465 (630)
546 (740)
981 (1,330)
65-40-315
40
173 (770) 157 (700)
198 (880)
308 (1,370) 664 (900)
465 (630)
546 (740)
981 (1,330)
80-50-160
50
236 (1,050) 214 (950)
259 (1,150) 409 (1,820) 723 (980)
516 (700)
590 (800)
1,069 (1,450)
80-50-200
50
236 (1,050) 214 (950)
259 (1,150) 409 (1,820) 723 (980)
516 (700)
590 (800)
1,069 (1,450)
80-50-250
50
236 (1,050) 214 (950)
259 (1,150) 409 (1,820) 723 (980)
516 (700)
590 (800)
1,069 (1,450)
80-50-315
50
236 (1,050) 214 (950)
259 (1,150) 409 (1,820) 723 (980)
516 (700)
590 (800)
1,069 (1,450)
100-65-160
65
292 (1,300) 270 (1,200) 330 (1,470) 517 (2,300) 774 (1,050)
568 (770)
620 (840)
1,143 (1,550)
100-65-200
65
292 (1,300) 270 (1,200) 330 (1,470) 517 (2,300) 774 (1,050)
568 (770)
620 (840)
1,143 (1,550)
100-65-250
65
292 (1,300) 270 (1,200) 330 (1,470) 517 (2,300) 774 (1,050)
568 (770)
620 (840)
1,143 (1,550)
100-65-315
65
292 (1,300) 270 (1,200) 330 (1,470) 517 (2,300) 774 (1,050)
568 (770)
620 (840)
1,143 (1,550)
125-80-160
80
355 (1,580) 324 (1,440) 393 (1,750) 620 (2,760) 826 (1,120)
590 (800)
671 (910)
1,217 (1,650)
125-80-200
80
355 (1,580) 324 (1,440) 393 (1,750) 620 (2,760) 826 (1,120)
590 (800)
671 (910)
1,217 (1,650)
125-80-250
80
355 (1,580) 324 (1,440) 393 (1,750) 620 (2,760) 826 (1,120)
590 (800)
671 (910)
1,217 (1,650)
125-80-315
80
355 (1,580) 324 (1,440) 393 (1,750) 620 (2,760) 826 (1,120)
590 (800)
671 (910)
1,217 (1,650)
125-80-400
80
355 (1,580) 324 (1,440) 393 (1,750) 620 (2,760) 826 (1,120)
590 (800)
671 (910)
1,217 (1,650)
125-100-200 100
472 (2,100) 427 (1,900) 528 (2,350) 825 (3,670) 907 (1,230)
649 (880)
752 (1,020) 1,342 (1,820)
125-100-250 100
472 (2,100) 427 (1,900) 528 (2,350) 825 (3,670) 907 (1,230)
649 (880)
752 (1,020) 1,342 (1,820)
125-100-315 100
472 (2,100) 427 (1,900) 528 (2,350) 825 (3,670) 907 (1,230)
649 (880)
752 (1,020) 1,342 (1,820)
125-100-400 100
472 (2,100) 427 (1,900) 528 (2,350) 825 (3,670) 907 (1,230)
649 (880)
752 (1,020) 1,342 (1,820)
150-125-250 125
562 (2,500) 504 (2,240) 618 (2,750) 978 (4,350) 1,084 (1,470) 774 (1,050)
981 (1,330) 1,578 (2,140)
150-125-315 125
562 (2,500) 504 (2,240) 618 (2,750) 978 (4,350) 1,084 (1,470) 774 (1,050)
981 (1,330) 1,578 (2,140)
150-125-400 125
562 (2,500) 504 (2,240) 618 (2,750) 978 (4,350) 1,084 (1,470) 774 (1,050)
981 (1,330) 1,578 (2,140)
200-150-250 150
708 (3,150) 641 (2,850) 787 (3,500) 1,236 (5,500) 1,291 (1,750) 907 (1,230)
1,069 (1,450) 1,888 (2,560)
200-150-315 150
708 (3,150) 641 (2,850) 787 (3,500) 1,236 (5,500) 1,291 (1,750) 907 (1,230)
1,069 (1,450) 1,888 (2,560)
200-150-400 150
708 (3,150) 641 (2,850) 787 (3,500) 1,236 (5,500) 1,291 (1,750) 907 (1,230)
1,069 (1,450) 1,888 (2,560)
Suction-piping checklist
Performance curve reference
CAUTION:
Vary the capacity with the regulating valve in the discharge line. Never throttle the flow from the suction
side. This action can result in decreased performance, unexpected heat generation, and equipment damage.
Net positive suction head available (NPSH
A
) must always exceed NPSH required (NPSH
R
) as shown on
the published performance curve of the pump.
Suction-piping checks
Check
Explanation/comment
Checked
Check that the distance between the inlet flange of
the pump and the closest elbow is at least five pipe
diameters.
This minimizes the risk of cavitation in
the suction inlet of the pump due to
turbulence.
See the Example sections for
illustrations.
Installation
32
Model IC, ICI, ICH, ICIH Installation, Operation, and Maintenance Manual