1.

Coupling guard – two equal halves (parts 1 and 2)

2.

Adjusting piece (part 3)

2. Remove the screws (2) that attach the two halves (parts 1 and 2) of the coupling guard.

1

2

3. Remove the screws (1) that attach the top half (part 1) of the coupling guard to the bearing cover.
4. Remove the top half (part 1) of the coupling guard.
5. Remove the adjusting piece (part 3).

Commissioning, Startup, Operation, and Shutdown

38

Model IC, ICI, ICH, ICIH Installation, Operation, and Maintenance Manual