Remove the coupling, Remove the back pull-out assembly, Emove the coupling – Goulds Pumps IC - IOM User Manual

Page 58: Emove the back pull-out assembly

Advertising
background image

You must drain the system if no valves are installed.

2. Open the drain valve.

Do not proceed until liquid stops coming out of the drain valve. If liquid continues to flow from the
drain valve, the isolation valves are not sealing properly and you must repair them before you proceed.

3. Leave the drain valve open and remove the drain plug located on the bottom of the pump housing.

Do not reinstall the plug or close the drain valve until the reassembly is complete.

4. Drain the liquid from the piping and flush the pump if it is necessary.
5. Disconnect all auxiliary piping and tubing.
6. Remove the coupling guard.

Remove the coupling

Remove the coupling in accordance with the recommendations of the coupling manufacturer.

Remove the back pull-out assembly

CAUTION:
Never remove the back pull-out assembly without assistance.

1. Is your bearing frame oil lubricated?

• If No: Proceed to step 2.
• If Yes:

1. Remove the bearing-frame drain plug (903.51) in order to drain oil from the bearing frame.
2. Replace the plug after the oil is drained.
3. Remove the oil reservoir, if equipped.

NOTICE:
Oil analysis should be part of a preventive maintenance program that determines the cause of a
failure. Save the oil in a clean container for inspection.

2. Place one sling from the hoist through the frame adapter (344) and a second sling from the hoist to

the bearing frame (330).

370F

330

901.11

901.42

344

120V

3. Remove the hold-down bolts of the bearing frame foot.
4. Remove the casing bolts.

Maintenance

56

Model IC, ICI, ICH, ICIH Installation, Operation, and Maintenance Manual

Advertising