Discharge piping checklist – Goulds Pumps IC - IOM User Manual

Page 36

Advertising
background image

Example: Elbow close to the pump suction inlet

Correct

Incorrect

The correct distance between the inlet flange of the pump and

the closest elbow must be at least five pipe diameters.

1

2

1.

Enough distance to prevent cavitation

2.

Eccentric reducer with a level top

Example: Suction piping equipment

Correct

Incorrect

1

2

3

4

5

1.

Suction pipe sloping upwards from liquid source

2.

Long-radius elbow

3.

Strainer

4.

Foot valve

5.

Eccentric reducer with a level top

1

1.

Air pocket, because the eccentric reducer is not
used and because the suction piping does not slope
gradually upward from the liquid source

Discharge piping checklist

Checklist

Check

Explanation/comment

Checked

Check that an isolation valve is

installed in the discharge line.

The isolation valve is required for:
• Priming
• Regulation of flow
• Inspection and maintenance of the pump
See Example: Discharge piping equipment for

illustrations.

Check that a check valve is installed in

the discharge line, between the

isolation valve and the pump discharge

outlet.

The location between the isolation valve and the

pump allows inspection of the check valve.

Installation

34

Model IC, ICI, ICH, ICIH Installation, Operation, and Maintenance Manual