Bearing maintenance, Lubricating oil requirements – Goulds Pumps IC - IOM User Manual

Page 54

Advertising
background image

Bearing maintenance

These bearing lubrication sections list different temperatures of pumped fluid. If your pump is ATEX
certified and the pumped fluid exceeds the permitted temperature values, then consult your ITT
representative.

Bearing lubrication schedule

Type of bearing

First lubrication

Lubrication intervals

Oil-lubricated bearings

Add oil before you install and start

the pump.
Change the oil after 200-300 hours

of operation, depending on

bearing temperature.

See the Oil change schedule table.

Grease-lubricated bearings

N/A

Every 4000 hours of operation or

once a year, whichever comes first
Every two years if the pump is left

idle

Oil change schedule

Oil must be changed at least once a year.

Bearing temperature

First oil change

Subsequent oil changes

Up to 140°F (60°C)

After 300 hours of operation

Every 8760 hours of operation

140°F to 176°F (60°C to 80°C)

After 300 hours of operation

Every 4000 hours of operation

176°F to 212°F (80°C to 100°C)

After 200 hours of operation

Every 3000 hours of operation

NOTICE:

• Strictly maintain the oil changing schedule if the pump is operating in an potentially explosive

environment.

• Change the oil every two years if the pump is left idle.
• Dispose of used oil in accordance with local environmental regulations.

Lubricating oil requirements

Oil quality requirements

Use a high-quality turbine oil with rust and oxidation inhibitors.

Lubricating oil type

• CLP46
• DIN 51517
• HD 20W/20 SAE

Symbol

DIN 51502

Kinematic viscosity at 104°F (40°C)

0.0713 ±0.006 in.

2

/sec

(46 ±4 mm

2

/sec)

Flash point (Cleveland)

347°F (175°C)

Setting point (Pourpoint)

5°F (-15°C)

Application temperature
(Contact your ITT representative to determine a

suitable type of lubrication if ambient temperatures

are below 14°F [-10°C].)

Higher than permitted bearing temperature

Oil quantity requirements

Bearing frame size

Oil quantity in quarts (liters)

24

0.53 (0.5 )

Maintenance

52

Model IC, ICI, ICH, ICIH Installation, Operation, and Maintenance Manual