Remove the seal-chamber cover, Emove the seal-chamber cover – Goulds Pumps IC - IOM User Manual
Page 61
922
412.21
230
210
940.31
NOTICE:
Crush hazard. Make sure that the back pull-out assembly cannot tip over.
Remove the seal-chamber cover
1. Remove the gland stud nuts.
2. Remove the seal-chamber stud nuts.
3. Remove the seal chamber (161).
4. Remove the shaft sleeve (524) if it is used.
The mechanical seal is attached to the sleeve.
NOTICE: Be careful with the stationary portion of the mechanical seal that is either clamped
between the backplate and the gland or seated in the seal-chamber bore. Failure to do so may result in
equipment damage.
5. Remove the rotary portion of the seal from the sleeve by loosening the setscrews and sliding it off the
sleeve.
Refer to the mechanical-seal instructions for more information.
6. Remove the gland (452), the stationary portion of the seal, and the O-ring (412.21).
Maintenance
Model IC, ICI, ICH, ICIH Installation, Operation, and Maintenance Manual