Lubricate the bearings with oil, Fill the bearing frame with oil, Fill the bearing frame with an optional oiler – Goulds Pumps IC - IOM User Manual

Page 45

Advertising
background image

Application temperature
(Contact your ITT representative to determine a

suitable type of lubrication if ambient temperatures

are below 14°F [-10°C].)

Higher than permitted bearing temperature

Oil quantity requirements

Bearing frame size

Oil quantity in quarts (liters)

24

0.53 (0.5 )

32

1.16 (1.1 )

42

1.48 (1.4 )

48

1.8 (1.7 )

Lubricate the bearings with oil

WARNING:
Make sure to properly lubricate the bearings. Failure to do so can result in excess heat generation, sparks,
and premature failure.

NOTICE:
The pump is not filled with oil when delivered. Fill with oil before operating the pump.

• Determine which procedure to use in order to fill the bearing frame with oil:

If...

Then...

The pump has an oil level sight glass (standard

design)

Use the "Fill the bearing frame with oil" procedure.

The pump has a constant level oiler (optional)

Use the "Fill the bearing frame with an optional

oiler" procedure.

Fill the bearing frame with oil

NOTICE:
Maintain an exact oil level. If the oil level is too high, the bearing temperature can increase. If the oil level
is too low, the bearing will not be properly lubricated and could cause operational problems.

1. Remove the oil filling plug.
2. Pour oil into the opening.
3. Fill until the oil level rises to the center of the oil level sight glass.

Fill the bearing frame with an optional oiler

NOTICE:
Maintain an exact oil level. If the oil level is too high, the bearing temperature can increase. If the oil level
is too low, the bearing will not be properly lubricated and could cause operational problems.

The constant level oiler is supplied loose.

Commissioning, Startup, Operation, and Shutdown

Model IC, ICI, ICH, ICIH Installation, Operation, and Maintenance Manual