Auxiliary-piping checklist

Precautions

WARNING:

• Cooling systems such as those for bearing lubrication and mechanical-seal systems must be operating

properly to prevent excess heat generation, sparks, and premature failure.

• Sealing systems that are not self-purging or self-venting, such as plan 23, require manual venting prior

to operation. Failure to do so will result in excess heat generation and seal failure.

NOTICE:
The mechanical seal must have an appropriate seal-flush system. Otherwise, excess heat generation and
seal failure can occur.

When to install

You may need to install auxiliary piping for bearing cooling, seal-chamber cover cooling, mechanical seal
flush, or other special features supplied with the pump. Consult the pump data sheet for specific auxiliary
piping recommendations.

Checklist

Check

Explanation/

comment

Checked

Check that the minimum flow for each component is 1 gpm (4 lpm).
If the bearing and seal chamber cover cooling are provided, then the

auxiliary piping must flow at 2 gpm (8 lpm).

Check that the cooling water pressure does not exceed 100 psig (7.0 kg/

cm

2

).

Final piping checklist

Check

Explanation/comment

Checked

Check that the shaft rotates smoothly.

Rotate the shaft by hand. Make sure there is no

rubbing that can lead to excess heat generation or

sparks.

Re-check the alignment to make sure that

pipe strain has not caused any

misalignment.

If pipe strain exists, then correct the piping.

Installation

36

Model IC, ICI, ICH, ICIH Installation, Operation, and Maintenance Manual