Bearing types

Use this table in order to determine the correct bearings for the pump. You can find the size of the bearing
frame in the data sheet or the order confirmation.

Bearing frame size

Radial bearing

Thrust bearing

24

6307 - C3

3307A - C3

32

6309 - C3

3309A - C3

42

6311 - C3

3311A - C3

48

6313 - C3

3313A - C3

Spare parts

Spare pumps kept for stand-by usage

When you stock spare, stand-by pumps, consider these guidelines:

• In plants where failure of a pump could endanger human life or cause damage to property or high

costs, you must keep a sufficient number of stand-by pumps in stock.

• Store stand-by pumps according to the instructions in Transportation and Storage.

Spare parts stock guidelines

When you stock spare parts, consider these guidelines:

• Stock spare parts in order to ensure two years of continuous operation.
• If no other guidelines apply, stock the recommended number of parts listed in the spare parts table.
• Make sure that you maintain an adequate number of spare parts, especially parts that require longer

delivery times:
• Mechanical seals
• Parts made from special materials
• Parts that need to be specially sized

• Store spare parts in dry, clean areas in their original packaging until you need them.

Number of spare parts to keep in stock

Component

Number of Pumps (includes stand-by pumps)

2

3

4

5

6/7

8/9

10+

Number of Spare Parts

Impeller

1

1

1

2

2

2

20% (see calculation note)

Wear ring

2

2

2

3

3

4

50% (see calculation note)

Shaft with key and

nuts

1

1

1

2

2

2

20% (see calculation note)

Ball bearing set

1

1

2

2

2

3

25% (see calculation note)

Shaft sleeve

2

2

2

3

3

4

50% (see calculation note)

Lantern ring

1

1

2

2

2

3

30% (see calculation note)

Packing ring

16

16

24

24

24

32

100% (see calculation note)

Casing gaskets

4

6

8

8

9

12

150% (see calculation note)

Other gaskets

4

6

8

8

9

10

100% (see calculation note)

Mechanical seals

1

1

2

2

2

3

25% (see calculation note)

Power end (bearing

frame, adapter, shaft,

bearings, and other

parts)

2

Calculation note
In order to determine the number of spare parts to stock for a part used on 10 or more pumps, use this
calculation:

Maintenance