Goulds Pumps IC - IOM User Manual

Page 60

Advertising
background image

230

161

a

2. Secure the rotor at the coupling end and loosen the impeller nut (922) (right-threaded).
3. Remove the impeller (230) with two screwdrivers or pry bars.

922

412.21

230

NOTICE:
Be sure to locate the pry bars under the impeller vanes in order to prevent damage to the impeller.

4. Remove the impeller key (940.31).
5. Place the back pull-out assembly in a vertical position before you proceed with the disassembly.

Maintenance

58

Model IC, ICI, ICH, ICIH Installation, Operation, and Maintenance Manual