Other methods of priming the pump

You can also use these methods in order to prime the pump:

• Prime by ejector
• Prime by automatic priming pump

Start the pump

CAUTION:

• Immediately observe the pressure gauges. If discharge pressure is not quickly attained, stop the driver,

reprime, and attempt to restart the pump.

• Observe the pump for vibration levels, bearing temperature, and excessive noise. If normal levels are

exceeded, shut down the pump and resolve the issue.

Before you start the pump, you must perform these tasks:

• Open the suction valve.
• Open any recirculation or cooling lines.

1. Fully close or partially open the discharge valve, depending on system conditions.
2. Start the driver.
3. Slowly open the discharge valve until the pump reaches the desired flow.
4. Immediately check the pressure gauge to ensure that the pump quickly reaches the correct discharge

pressure.

5. If the pump fails to reach the correct pressure, perform these steps:

a) Stop the driver.
b) Prime the pump again.
c) Restart the driver.

6. Monitor the pump while it is operating:

a) Check the pump for bearing temperature, excessive vibration, and noise.
b) If the pump exceeds normal levels, then shut down the pump immediately and correct the

problem.
A pump can exceed normal levels for several reasons. See Troubleshooting for information about
possible solutions to this problem.

7. Repeat steps 5 and 6 until the pump runs properly.

Limits of operation

Flow limits

These flow limits are valid unless other data is available in the curves or data sheets:

Q

min

= 0.1 x Q

BEP

Short-term operation

Q

min

= 0.3 x Q

BEP

Continuous operation

Q

max

= 1.2 x Q

BEP

Short-term operation as long as NPSH

facility

>

NPSH

pump

+ 1.64 ft (0.50 m)

Permitted number of starts

Do not start the pump more than the number of times shown in this chart: