Check the rotation – Goulds Pumps IC - IOM User Manual

Page 41

Advertising
background image

6. Remove the screws (4) that attach the bottom half (part 2) of the coupling guard to the bearing cover

(1).

1

2

3

4

1.

Bearing cover

2.

Coupling

3.

Motor

4.

Screws

7. Remove the bottom half (part 2) of the coupling guard.

Check the rotation

WARNING:

• Operating the pump in reverse rotation can result in the contact of metal parts, heat generation, and

breach of containment.

• Always disconnect and lock out power to the driver before you perform any installation or

maintenance tasks. Failure to disconnect and lock out driver power will result in serious physical
injury.

1. Lock out power to the driver.
2. Make sure that the coupling hubs are fastened securely to the shafts.

Commissioning, Startup, Operation, and Shutdown

Model IC, ICI, ICH, ICIH Installation, Operation, and Maintenance Manual

39