Check the rotation – Goulds Pumps IC - IOM User Manual
Page 41
6. Remove the screws (4) that attach the bottom half (part 2) of the coupling guard to the bearing cover
(1).
1
2
3
4
1.
Bearing cover
2.
Coupling
3.
Motor
4.
Screws
7. Remove the bottom half (part 2) of the coupling guard.
Check the rotation
WARNING:
• Operating the pump in reverse rotation can result in the contact of metal parts, heat generation, and
breach of containment.
• Always disconnect and lock out power to the driver before you perform any installation or
maintenance tasks. Failure to disconnect and lock out driver power will result in serious physical
injury.
1. Lock out power to the driver.
2. Make sure that the coupling hubs are fastened securely to the shafts.
Commissioning, Startup, Operation, and Shutdown
Model IC, ICI, ICH, ICIH Installation, Operation, and Maintenance Manual
39