Packed stuffing-box maintenance, Ked stuffing-box maintenance – Goulds Pumps IC - IOM User Manual
Page 56
CAUTION:
Never operate the pump without liquid supplied to mechanical seal. If you run a mechanical seal dry, even
for a few seconds, this can cause seal damage. Physical injury can occur if a mechanical seal fails.
Reference drawing
The manufacturer supplies a reference drawing with the data package. Keep this drawing for future use
when you perform maintenance and seal adjustments. The seal drawing specifies the required flush fluid
and attachment points.
Before you start the pump
Check the seal and all flush piping.
Mechanical seal life
The life of a mechanical seal depends on the cleanliness of the pumped fluid. Due to the diversity of
operating conditions, it is not possible to give definite indications as to the life of a mechanical seal.
Packed stuffing-box maintenance
WARNING:
• Packed stuffing boxes are not allowed in an ATEX-classified environment.
• Never attempt to replace the packing until the driver is properly locked out and the coupling spacer is
removed.
Accepted leakage rate
It is not necessary to shut down or disassemble the pump to inspect the packing operation. During normal
operation the packing should leak approximately 30-100 drops per minute.
Adjustment of gland
Adjust the gland if the leakage rate is greater than or less than the specified rate.
Evenly adjust each of the two gland bolts with a one-quarter (1/4) turn until the desired leakage rate is
obtained. Tighten the bolts to decrease the rate. Loosen the bolts to increase the rate.
Tightening of packing
NOTICE: Never over-tighten packing to the point where less than one drop per minute is observed.
Over-tightening can cause excessive wear and power consumption during operation.
If you cannot tighten the packing to obtain less than the specified leakage rate, then replace the packing.
Maintenance
54
Model IC, ICI, ICH, ICIH Installation, Operation, and Maintenance Manual