Couple the pump and driver, Install the coupling guard – Goulds Pumps IC - IOM User Manual

Page 42

Advertising
background image

3. Make sure that the coupling spacer is removed.

The pump ships with the coupling spacer removed.

4. Unlock power to the driver.
5. Make sure that everyone is clear, and then jog the driver long enough to determine that the direction

of rotation corresponds to the arrow on the bearing housing, or close-coupled frame.

6. Lock out power to the driver.

Couple the pump and driver

WARNING:
Always disconnect and lock out power to the driver before you perform any installation or maintenance
tasks. Failure to disconnect and lock out driver power will result in serious physical injury.

Couplings must have proper certification to be used in an ATEX classified environment. Use the
instructions from the coupling manufacturer in order to lubricate and install the coupling.

Install the coupling guard

1. Identify the parts of the coupling guard.

IMPORTANT: For pumps with CE conformance, the coupling guard fasteners have devices that
keep them from completely detaching from the guard or the pump. Do not remove these devices or
separate the fasteners from the guard or the pump.

1

2

1.

Coupling guard – two equal halves (parts 1 and 2)

2.

Adjusting piece (part 3)

2. Screw the bottom half (part 2) of the coupling guard to the bottom of the bearing cover (1).

Commissioning, Startup, Operation, and Shutdown

40

Model IC, ICI, ICH, ICIH Installation, Operation, and Maintenance Manual

Advertising