7.2 Specifying the Machine Settings

7

bizhub 161f

7-3

Us

in

g th

e Uti

lit

y

Mod

e

Chap

ter

7

7.2

Specifying the Machine Settings

From the “MACHINE SETTING” menu, various settings for the machine’s operating
environment can be specified. Refer to the following table for details on each
function.

No.

Name

Description

1

AUTO PANEL RESET

Whether the Auto Panel Reset function is disable or the time (0.5 min,
1 min, 2 min, 3 min, 4 min, or 5 min) until the machine is reset after
finishing copying/printing or after performing the last operation can be
selected. If the Auto Panel Reset function is enabled, all functions are
automatically reset to their default settings.
• The factory default setting is 1 min.

2

ENERGY SAVE MODE

If the machine performs no operations for a set length of time, it will
automatically enter the Energy Save mode. The length of time until the
machine enters Energy Save mode can be set between 1 min and
240 min (in 1 min increments).
• The factory default setting is 15 min.

3

DENSITY (ADF)

The scanning density when using the Automatic Document Feeder
can be adjusted.
Mode 1: For printing lighter copies of dark documents to avoid
darkening of copies.
Mode 2: For printing copies with same density as documents.
• The factory default setting is “Mode 1”.

4

DENSITY (BOOK)

The density when scanning from the Original Glass can be adjusted.
Mode 1: For printing copies with same density as documents.
Mode 2: For printing lighter copies of dark documents to avoid
darkening of copies.
• The factory default setting is “Mode 1”.

5

PRINT DENSITY

The copy/print density can be adjusted to one of six levels between
–3 and +3. With the normal print density at 0, choose a smaller number
for a lighter print or choose a higher number for a darker print.
• The factory default setting is “0” (Normal).

6

LCD CONTRAST

The brightness of the display can be set to one of four levels between
–1 and +2.
• The factory default setting is “0” (Normal).

7

LANGUAGE

The display language can be selected.
• The factory default setting is “English”.

8

LAMP OFF TIME

The time until the exposure lamp goes off can be adjusted.
Mode 1: When four hours have passed since the last operation was

performed

Mode 2: When the machine enters Energy Save mode
• The factory default setting is “Mode 1”.

9

BUZZER VOLUME

This function can be used to set the volume of alarms and the beep
sounded when a key is pressed.
• The manufacturer’s default setting is “LOW”.

0

INITIAL MODE

This function can be used to set the mode (Copy mode or Fax mode)
that the machine starts up in or returns to after the Control Panel is
reset.
• The manufacturer’s default setting is “COPY”.