Instruction 24-9448

4-4

Operation

4.4 Sampling Point

FORCED AIR FURNACE – For atmospherc burner

or gravty vented, forced ar heatng equpment

wth a clamshell or sectonal heat exchanger de-

sgn, test each of the exhaust ports at the top of the

heat exchanger. The probe should be nserted back

nto each of the exhaust ports to obtan a flue-gas

sample, before any dluton ar s mxed n.
HOT WATER TANK – Domestc hot water tanks

wth the ‘bell’ shaped draft dverter can be ac-

curately tested by nsertng the probe tp drectly

nto the top of the fre tube below the dverter.
80% EFFICIENCY FAN ASSIST OR POWER VENTED

– Combuston testng of fan assst or power vented,

furnaces/bolers should be done through a hole drlled

n the vent mmedately above the nducer fan.
90% EFFICIENCY CONDENSING – Condens-

ng furnaces/bolers can be tested through a hole

drlled n the plastc vent ppe (when allowed by

the manufacturer or local authorty of jursdcton)

or taken from the exhaust termnaton.
ATMOSPHERIC OR GRAVITY VENTED BOILER

– Bolers, whch have a ‘bell’ shaped draft dverter

on top, should be tested drectly below the dverter

through a hole drlled n the vent connector.

Forced Air Furnace

Hot Water Tank

Atmospheric or Gravity

Vented Boiler

80% Eff. Fan Assist or

Power Vented

90% Eff. Condensing

O

2

,

CO,

Stack Temp.

Undiluted Flue

Gas Sample Taken

Under Draft

Diverter in Top

of Fire Tube

O

2

, CO,

Stack Temp.

O

2

, CO,

Stack Temp.

Combustion Air

Sampling Point

O

2

, CO,

Stack Temp.