Instruction 24-9448

1-1

Introduction

1 Introduction
1.1 PCA 2 General Description

The PCA 2 s a commercal-grade hand-held combuston and emssons

analyzer desgned for on-demand samplng of lght ndustral, nsttu-

tonal, commercal and resdental furnaces, applances, and bolers. The

basc nstrument s suppled wth a probe and hose assembly, nstructon

manual, factory calbrated smart sensors, 4 'AA' alkalne batteres, Data

Download Software wth USB cable and carryng case.

Because of the PCA 2’s ablty to measure up to four gases smultaneously,

t s the perfect tool for servce techncans, nspectors and boler contrac-

tors who need to determne combuston effcency, excess ar, stack gas O

2

and CO levels, stack temperature, draft, and dfferental pressure. The

analyzer can also drectly measure and dsplay NO, NO

2

and SO

2

wth the

nstallaton of the approprate sensors. Combuston effcency calculatons

can be conducted for the followng fuels: natural gas, ol #2, ol #4, ol #6,

propane, coal, wood, kerosene, bagasse, and dgester gas. A large backlt

graphcal dsplay shows up to eght combuston test values smultaneously,

and ncludes a zoom capablty that provdes an extra large dsplay of just

the O

2

, CO, and combuston effcency values.

Smart sensor technology allows a new sensor to be nstalled n the feld

wthout havng to calbrate the analyzer before use. New and nnovatve

probe and analyzer desgns allow the PCA 2 to be easly servced, thus

lowerng the cost of ownershp.

Advanced data storage and communcaton features allow the operator

to store up to 500 ndvdual combuston test records, whch can later be

recalled for vewng, prntng, or downloadng to a personal computer. In

ts data loggng mode, the analyzer can store an addtonal 500 data logged

records.

An optonal AC power adapter allows the analyzer to run contnuously for

data loggng purposes.

The optonal sample condtonng probe s recommended when measurng

NO

2

and SO

2

to ensure the hghest degree of measurement accuracy.

Advertising