2n® smartgate parameters configuration, Pc connection, 2n® smartgate parameter programming – 2N Fixed line replacement with 2N SmartGate - Manual v1.1.2 User Manual

Page 24: Telephone line based programming, 1 2n® smartgate parameters configuration, 2n® smartgate parameters configuration 3.1

Advertising
background image

2N® SmartGate parameters configuration

3.1

24

3.1 2N® SmartGate parameters

configuration

PC Connection

You have got a serial cable for PC connection. It is a modem cable where all of the 9
pins are 1:1 interconnected – in case you want to use another cable.

Caution

Make sure that a longer cable works properly to avoid errors at high
transmission rates.

2N® SmartGate Parameter Programming

Most of SmartGate‟s parameters have such default values that meet most users‟
demands and need not be changed. Usually you have to program routing tables
according to 2N® SmartGate usage. There are two possibilities how to program
SmartGate:

Use phone line and DTMF programming from connected phone set. This is not

applicable for all parameters

Use a PC with the PCManager installed. Using this way all parameters

supported by 2N® SmartGate can be programmed.

Telephone Line based Programming

1. Hook off the telephone, you can hear the dial tone or the busy tone, and the

Line LED starts flashing.

2. Enter the service password (12345 by default, can be changed) with the DTMF;

to cancel a wrong password hang up before sending the

character. To

confirm password enter a

.

3. If you have entered a correct password, you hear the confirmation tone. If not,

the dialed number may be sent to the GSM network as a call. To prevent this,
hang up when you do not hear the confirmation tone.

4. 2N® SmartGate shall remain in the programming mode until hang-up.

5. Enter the number of the parameter to be programmed and press a

. If the

parameter number is correct, you can hear the confirmation tone, if not, you
get the refusal tone and can re-enter the parameter number.

6. When the parameter number is confirmed, enter the allowed parameter value

and press a

. If the parameter value is in the allowed range, you can hear

the saving tone, if not, you get the refusal tone. You can enter another
parameter number in either case.

Advertising