Table of parameters 3.2, 32 tone settings – 2N Fixed line replacement with 2N SmartGate - Manual v1.1.2 User Manual

Page 32

Advertising
background image

Table of Parameters

3.2

32

Tone settings

Dial tone – Double frequency tone[Hz]

Function No.: -

Parameter can be set for all three types of tone (Dial tone, Busy
tone,Ringbacktone). This parameter is intended for switching between single
tone and double tone setting. When the parameter is set, the second frequency
of appropriate tone must be set too. When this parameter isn‟t set, the second
frequency is automatically set to the same value, which results in single tone
generation. This parameter can‟t be set using phone line programming. When
the phone line programming is used for frequency change, both tones must be
set (for single frequency to the same value).

Setting options:

YES/NO

Default setting:

NO

Dial tone – frequency 1[Hz]

Function No.: 120

Setting of frequency 1 of dial tone. This tone is generated after Off-Hook in case
2N® SmartGate is ready to accept dialing.

Setting options:

1-3400 Hz

Setting step:

1 HzD

efault setting:

425 Hz

Dial tone – frequency 2[Hz]

Function No.: 121

Setting of frequency 2 of dial tone.

Setting options:

1-3400 Hz

Setting step:

1 Hz

Default setting:

425 Hz

Dial tone - cadence

Function No.: 122

Dial tone cadence setting.

Setting options:

Continuous ( 0) -2N® SmartGate generate continuous
dial tone
Morse A (1) -2N® SmartGate generate dial tone with
330/330/660/660 ms timing

Default setting:

Continuous

Busy tone – frequency 1[Hz]

Function No.: 123

Setting of frequency 1 of busy tone.

Setting options:

1-3400 Hz

Setting step:

1 Hz

Default setting:

425 Hz

Busy tone – frequency 2[Hz]

Function No.: 124

Setting of frequency 2 of busy tone.

Setting options:

1-3400 Hz

Setting step:

1 Hz

Default setting:

425 Hz

Advertising