Table of Parameters

3.2

30

3.2 Table of Parameters

All programmable parameters are listed in this section. Each parameter is
accompanied with the unit used, function number (if avaliable) for programming via
a telephone line, description of SmartGate's behavior, setting options, setting step
and default (initialization) value.

Numeric parameters must be set in unit listed in the parameter description. For
parameters with different setting are values defined in the parameters description
(for phone line programming in parenthesis). When phone line programming is

used, character

can‟t be included in the string, because it is dedicated for

confirmation of the new parameter value.

Telephone interface FXS parameters

Dialing parameters

Type of dialing

Function No.: 100

Select the dialing type to be received by 2N® SmartGate on the FXS interface.
2N® SmartGate accepts only the selected type of dialing, ignoring the others.

Setting options:

DTMF (0) -2N® SmartGate receives tone dialing only.
Pulse (1) -2N® SmartGate receives pulse dialing only

Default setting:

DTMF

Timeout for dialing end recognize [s] Function No.: 101

Timeout during which 2N® SmartGate waits for further digits to be dialed. It
starts to establish connection when this timeout passes.

Setting options:

1-255 s

Setting step:

1 s

Default setting:

5 s

Minimal On Hook [ms]

Function No.: 102

The minimum line current break that 2N® SmartGate evaluates as hang-up.

Setting options:

100-25500 ms

Setting step:

100 ms

Default setting:

500 ms