Telephone interface fxo parameters, Table of parameters 3.2, Babycall“ – automatic call – 2N Fixed line replacement with 2N SmartGate - Manual v1.1.2 User Manual

Page 35: Dialing parameters

Advertising
background image

Table of Parameters

3.2

35

Replace character + in CLI by

Function No.: 149

If this parameter is filled, the + character in the international prefix of CLI is
replaced by the defined string. The + character can neither be transmitted by
the FSK protocol nor dialed by the DTMF from a terminal.

Setting options:

0-4 characters (0-9,*,#)

Default setting:

blank

„BabyCall“ – Automatic call

BabyCall number

Function No.: 180

A number to be dialed for the automatic call function. If this item is blank, the
function is disabled.

Setting options:

0-20 characters (0-9,*,#,+)

Default setting:

blank

BabyCall timeout [s]

Function No.: 181

Time between line Off-Hook and automatic call beginning (if enabled). During
this timeout 2N® SmartGate waits for dialing that cancels the automatic call.
You can make standard call if the BabyCall function is enabled.

Setting options:

0-255 s

Setting step:

1 s

Default setting:

0 s

Telephone interface FXO parameters

Dialing parameters

Number of rings before Off-Hook

Function No.: 200

If 2N® SmartGate is programmed as FXO gateway, parameter sets the count of
rings before Off-Hook.

Setting options:

1-255

Step:

1

Default setting:

1

Time for dialing start

Function No.: 202

If 2N® SmartGate is programmed as FXO gateway, parameter defines timeout
for first dialing digit. After timeout 2N® SmartGate hangs up the line.

Setting options:

1-255 s

Step:

1 s

Default setting:

15 s