Telephone interface fxo (for pbx extension line), Dial thru parameters, Sms sending input – 2N Fixed line replacement with 2N SmartGate - Manual v1.1.2 User Manual

Page 79: Technical parameters 5.1

Advertising
background image

Technical Parameters

5.1

79

Telephone connector type

RJ 12, 6/2

Line impedance

600 

Loop voltage on hook

48 V DC

Loop current

max. 40 mA

Loop resistance

max. 800 

Tone frequency

adjustable, default 425 Hz

Dialing type

tone (DTMF) or pulse

Ringing voltage

42 Vrms 50/25 Hz

Calling line identification

CLI during ringing according to ETSI FSK

Tariff pulses

f=16/12 kHz ; Umin=100 mVef on 200 

Answer supervision

polarity reversal, 12/16 kHz pulses

Telephone Interface FXO (for PBX extension line)

Interface type

2-wire analog, FXO

Telephone connector type

RJ 12, 6/2

Line impedance

Zr (TBR21) or 600  (According to model of Gateway)

On-hook DC resistance

1 M

Off-hook line current

10 - 65 mA

Off-hook line voltage (typ.)

4,5 V for 25 mA

Dial tone frequency

adjustable, default 425 Hz

Dialing type

tone (DTMF)

Ringing voltage

Min. 20 Vrms 25-50 Hz

Ringing impedance

4 - 10 k / 50 Hz

Dial thru parameters

Voltage drop (typ.)

1,7V / 25 mA

Closed loop resistance (typ.) 6 

SMS Sending Input