Table of Parameters

3.2

37

Beep after dialing end

Function No.: 203

If 2N® SmartGate is programmed as FXO gateway, parameter enables a beep to
signal the end of dialing (beginning of outgoing call establishing).

Setting options:

YES(1)/NO(0)

Default setting:

YES

Signaling

Busy tone detection

Function No.: 210

Set number of busy tone periods for detection of call disconnection from your
PBX. The "0" setting disables busy tone detection. For reliable detection is
recommended to use value 3 or more.

Setting options:

0-255

Step: 1

Default setting:

4

Continuous tone detection [ms]

Function No.: -

Set duration of constant frequency continuous tone for detection of call

disconnection from your PBX. The "0" setting disables continuous tone
detection.

Setting options:

0-8900 ms

Step:

35 ms

Default setting:

2030 ms

Tone settings

Dial tone – Double frequency tone[Hz]

Function No.: -

Parameter can be set for all three types of tone (Dial tone, Busy tone,
Ringbacktone). This parameter is intended for switching between single tone and
double tone setting. When the parameter is set, the second frequency of
appropriate tone must be set too. When this parameter isn‟t set, the second
frequency is automatically set to the same value, which results in single tone
generation. This parameter can‟t be set using phone line programming. When
the phone line programming is used for frequency change, both tones must be
set (for single frequency to the same value).

Setting options:

YES/NO

Default setting:

NO

Dial tone – frequency 1[Hz]

Function No.: 220

Setting of frequency 1 of dial tone. This tone is generated after Off-Hook in case
2N® SmartGate is ready to accept dialing.

Setting options:

1-3400 Hz

Setting step:

1 HzD

efault setting:

425 Hz