E84AYCEC communication manual (Ethernet POWERLINK)

Safety instructions

Device and application-specific safety instructions

12

L

EDS84AYCEC EN 3.0 - 09/2012

 Only qualified personnel may work with and on Lenze drive and automation

components. According to IEC 60364 or CENELEC HD 384, these are persons ...
– who are familiar with the installation, assembly, commissioning and operation of

the product.

– who have the corresponding qualifications for their work.
– who know all regulations for the prevention of accidents, directives and laws

applicable on site and are able to apply them.

2.2

Device and application-specific safety instructions

 During operation, the communication module must be firmly connected to the

standard device.

 Always use a separate power supply unit safely separated according to EN 61800-5-1

("SELV/PELV") in every control cabinet for external voltage supply.

 Only use cables that comply with the listed specifications.

Ethernet cable specification

( 33)

2.3

Residual hazards

Protection of persons

 If the Inverter Drives 8400 are operated on a phase-earthed mains with a rated mains

voltage of  400 V, external measures need to be implemented in order to ensure

protection against accidental contact.

Protective insulation

( 17)

Device protection

 The communication module contains electronic components that can be damaged or

destroyed by electrostatic discharge.

Installation

( 22)

Documentation for the standard device, control system, system/machine
All other measures prescribed in these documents must also be implemented.

Observe the safety instructions and application notes specified in the

documents.