C13003 | 0x1e40.5 ip address router, C13004 | 0x1030.5 mac address, C13004 – Lenze E84AYCEC User Manual

Page 67: Are displayed on the, E84aycec communication manual (ethernet powerlink)

Advertising
background image

EDS84AYCEC EN 3.0 - 09/2012

L

67

E84AYCEC communication manual (Ethernet POWERLINK)

Parameter reference

Parameters of the communication module

C13003

C13004

Parameter | Name:

C13003 | 0x1E40.5 IP Address Router

Data type: UNSIGNED_32

Index: 11572

d

= 2D34

h

The code declares the IP address of the router which connects the EPL segment to the higher-level network. The

standard entry corresponds to the standard router address of the EPL specification:
192.168.100.254

Permissible entries replace the lowest-order byte of the standard entry with the EPL address of the node which has

the function of a router.
Setting range

(min. value | unit | max. value)

0.0.0.0

(0x00000000)

255.255.255.255

(0xFFFFFFFF)

Subcodes

Lenze setting

Info

C13003/1

3232261374

IP address router

• Lenze setting: 0xC0A864FE = 192.168.100.254

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13004 | 0x1030.5 MAC Address

Data type: OCTET_STRING

Index: 11571

d

= 2D33

h

The code indicates the physical address (MAC address) of the Ethernet interface of the communication module.

When the communication module is produced, the MAC address is assigned unequivocally worldwide and provides

addressing on the lowest level.
Subcodes

Info

C13004/1

MAC Address (octet string[6])

00-0A-86-xx-yy-zz

• 00-0A-86 = Lenze

• xx-yy-zz = consecutive number

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Advertising