2 electrical installation, 1 wiring according to emc guidelines, Electrical installation – Lenze E84AYCEC User Manual

Page 26: Wiring according to emc guidelines

Advertising
background image

E84AYCEC communication manual (Ethernet POWERLINK)

Installation

Electrical installation

26

L

EDS84AYCEC EN 3.0 - 09/2012

5.2

Electrical installation

5.2.1

Wiring according to EMC guidelines

In typical systems a standard shielding of the Ethernet cable is sufficient.
In environments with very strong interferences, the EMC compatibility can be improved by

an additional earthing of the cable shield on both sides.
Observe the following notes:

1. Remove the plastic sheath of the cable at a length of 2 cm.
2. Fasten the cable shield to the shield support of the standard device.

Documentation for the standard device, control system, system/machine
Observe the notes and wiring instructions provided therein.