C13029 | 0x1f81 node assignment, E84aycec communication manual (ethernet powerlink) – Lenze E84AYCEC User Manual

Page 69

Advertising
background image

EDS84AYCEC EN 3.0 - 09/2012

L

69

E84AYCEC communication manual (Ethernet POWERLINK)

Parameter reference

Parameters of the communication module

C13029

The describing bit field has the following structure:

Parameter | Name:

C13029 | 0x1F81 Node Assignment

Data type: UNSIGNED_32

Index: 11546

d

= 2D1A

h

The code declares managing node, diagnostic device, and router, and describes their properties.
Value is bit-coded:

Bit 0 ... 31 see below

Subcodes

Lenze setting

Info

C13029/1

2147483661

EPL node assignment managing node

Lenze setting (hex): 0x8000000D

C13029/2

0

EPL node assignment diagnostic device

Lenze setting (hex): 0x00000000

C13029/3

2147483655

EPL node assignment router

Lenze setting (hex): 0x80000007

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Bit

Value

Description

0 (LSB)

0

EPL node with this ID does not exist.

1

EPL node with this ID exists.

1

0

EPL node with this ID is not a controlled node.

1

EPL node with this ID is a controlled node.

2

0

On detection of a booting controlled node, the application will not be informed.

1

On detection of a booting controlled node, the application will be informed and the

controlled node will be started.

3

0

Optional controlled node

1

Obligatory controlled node

4

0

The managing node is allowed to send reset commands.

1

The managing node must not send any reset command.

5

0

Software version verification of the controlled node is not required.

1

Software version verification of the controlled node is required.

6

0

Automatic application software update is not allowed.

1

Automatic application software update is allowed.

7

-

Reserved / No function

8

0

Isochronously accessed controlled node

1

Asynchronously accessed controlled node (bit 9 is irrelevant)

9

0

Continuously accessed controlled node

1

Multiplex EPL nodes are supported.

10

0

No "Ethernet POWERLINK to standard Ethernet" router function.

1

The device can be used as an "Ethernet POWERLINK to standard Ethernet" router (router

type 1).

11

0

No "Ethernet POWERLINK to fieldbus" router function.

1

The device can be used as an "Ethernet POWERLINK to fieldbus" router (router type 1).

12

0

The managing node does not send any PRes frames

1

The managing node sends PRes frames

13 ... 30

-

Reserved / No function

31 (MSB) 0

Bits 0 ... 30 inhibited

1

Bits 0 ... 30 enabled

Advertising