1 access to process data / pdo mapping, Access to process data / pdo mapping, E84aycec communication manual (ethernet powerlink) – Lenze E84AYCEC User Manual

Page 46

Advertising
background image

E84AYCEC communication manual (Ethernet POWERLINK)

Process data transfer

Access to process data / PDO mapping

46

L

EDS84AYCEC EN 3.0 - 09/2012

7.1

Access to process data / PDO mapping

Process data (MCI-PDOs) are transferred via the MCI interface.

 A maximum of 16 words are exchanged per direction.
 The process data are accessed via the port blocks LP_MciIn and LP_MciOut. These port

blocks are also referred to as process data channels.

 The port block LP_MciIn maps the received MCI-PDOs.
 The port block LP_MciOut maps the MCI-PDOs to be sent.
 The port/function block interconnection for the process data objects (PDO) is carried

out with the Lenze »Engineer«.

[7-1]

Outer and inner data transfer between bus system, controller and application

/3B0FL,Q

"

E&WUOB%

E&WUOB%

Z&WUO

E,QB%

E,QB%

Z,Q

Z,Q

GQ,QBS

/3B0FL2XW

E6WDWHB%

E6WDWHB%

Z6WDWH

E2XWB%

E2XWB%

Z2XW

Z2XW

GQ2XWBS

"

)LHOGEXV



$SSOLFDWLRQ

)%LQWHUFRQQHFWLRQ

&RPPXQLFDWLRQPRGXOH

0&,LQWHUIDFH

Software manual / »Engineer« online help for the Inverter Drive 8400
Here you can find detailed information on the port/function block

interconnection in the »Engineer« and on the port blocks.

Advertising