E84aycec communication manual (ethernet powerlink) – Lenze E84AYCEC User Manual
Page 19
Advertising
EDS84AYCEC EN 3.0 - 09/2012
L
19
E84AYCEC communication manual (Ethernet POWERLINK)
Technical data
Protective insulation
Example
Which type of protective insulation is used between the bus terminal of the device module
in slot MCI and the X100 mains terminal?
The separate potential area with the better protective insulation is decisive.
– The separate potential area of the bus terminal of the device module has a
"functional insulation".
– The separate potential area of the mains terminal has a "reinforced insulation".
Result: The insulation between the X100 mains terminal and the bus terminal is a
"reinforced insulation".
Advertising