E84AYCEC communication manual (Ethernet POWERLINK)

Technical data

Ethernet POWERLINK communication data

20

L

EDS84AYCEC EN 3.0 - 09/2012

4.3

Ethernet POWERLINK communication data

Communication time
The communication time is the time between the start of a request and the arrival of the

corresponding response.
The communication times in the Ethernet POWERLINK network depend on ...

 the processing time in the controller;
 the telegram runtime (baud rate / telegram length);
 the nesting depth of the network.

Processing time in the controller

There are no interdependencies between parameter data and process data.

Field

Values

Min. cycle time

400 s

Total cycle times

0.4 / 0.5 / 1.0 / 2.0 / 3.0 … 20.0 ms

Buffer size

• Tx-iso: max. 1490 bytes

• Rx-iso: max. 1490 bytes

(max. 32 bytes of PDO user data)

Delay time

• Controlled node (T

Preq

- T

Res

): approx. 2.6 s

• Controlled node (T

SoA

- T

ASnd

): approx. 2.6 s

Frame size

Max. asynchronous frame size (MTU): 1518 bytes

SDO communication method

UDP/IP or ASND

Number of RPDOs

Max. 6 channels

RPDO user data per application (all

RPDOs)

Max. 16 objects (max. 32 bytes)

Number of TPDOs

1 channel (data access of all nodes by broadcasting)

TPDO user data per application

Max. 16 objects (32 bytes)

CN operating modes

Support of ...

• Multiplex CNs

• Optional CNs

Data

Processing time

Process data

approx. 2 ms

+ 0 ... 1 ms

+ 1 ... x ms

Update cycle

Processing time in the module

Runtime of the application task of the technology

application used (tolerance)

Parameter data

approx. 30 ms + 20 ms tolerance (typical)

• For some codes, the processing time may be longer (see software

manual/»Engineer« online help for the Inverter Drive 8400).