Diagnostic data

 Pending diagnostic data are signalled from the controlled node to the managing node

by means of an emergency message.

Code

C13887

serves to suppress sending emergency messages to the managing node.

You can select which type of error is to be suppressed.

 Errors and warnings in the Inverter Drive 8400 and the plugged communication

module are sent to the managing node as extended diagnostic messages.

 The diagnostic data are visible via the PLC Engineering software.

Bytes

Meaning

Value [hex]

1 ... 6

Diagnostic block header

0x0010 001C 0100

7 ... 8

Alarm type

0x0001 (Diagnosis)

9 ... 12

API (Application Programming Interface)

0x0000 0000

13, 14

Slot number

0x0001 / 0x0002

15, 16

Subslot number

0x0001

17 ... 20

Module ID

ID corresponding to module

21 ... 24

Submodule number

ID corresponding to module

25, 26

Alarm specification

0xB000

27, 28

User structure ID

0x0001

29 ... 32

Error code