C13897 | profisafe: target address, C13899 | station address, C13900 | firmware product type – Lenze E94AYCPM User Manual

Page 100: C13901 | firmware compilation date, C13902 | firmware version, C13899, Becom, 14 parameter reference

Advertising
background image

14

Parameter reference

14.2

Parameters of the communication module for slot MXI1

100

Lenze · E94AYCPM communication module (PROFIBUS®) · Communication Manual · DMS 12.0 EN · 11/2012 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C13897

C13899

C13900

C13901

C13902

Parameter | Name:

C13897 | PROFIsafe: Target address

Data type: UNSIGNED_16

Index: 10678

d

= 29B6

h

Setting of the PROFIsafe target address

• Only required if the SM301 (E94AYAE) safety module is used.

• A unique PROFIsafe target address must be assigned to each controller.

Setting range

(min. value | unit | max. value)

Lenze setting

1

65534 1

;

Read access ; Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX ; COM … MOT

Parameter | Name:

C13899 | Station address

Data type: UNSIGNED_8

Index: 10676

d

= 29B4

h

Optional setting of the station address (instead of setting via DIP switches 1 ... 64)

• The station address set here only becomes effective if the DIP switches 1 ... 64 have been set to OFF prior to mains

switching.

• The active station address is displayed under

C13864

.

Note: A change of the station address will not be effective until the " Save parameter set" device command has been

executed and another mains switching for the communication module/controller has been performed.



Setting the station address ( 31)

Setting range

(min. value | unit | max. value)

Lenze setting

3

126 3

;

Read access ; Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX ; COM … MOT

Parameter | Name:

C13900 | Firmware product type

Data type: VISIBLE_STRING

Index: 10675

d

= 29B3

h

Display of the product type (string with a length of 8 bytes)

The following identification code is displayed: "E94AFCPM".

;

Read access … Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Parameter | Name:

C13901 | Firmware compilation date

Data type: VISIBLE_STRING

Index: 10674

d

= 29B2

h

Display of the compilation date of the firmware (string with a length of 20 bytes)

The date ("MMM DD YYYY") and time ("hh:mm:ss") are displayed, e.g. "Mar 21 2005 12:31:21".

;

Read access … Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Parameter | Name:

C13902 | Firmware version

Data type: VISIBLE_STRING

Index: 10673

d

= 29B1

h

Display of the firmware version (string with a length of 5 bytes)

Example: "01.21"

;

Read access … Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Advertising