3. Click the Edit PDO button. The Process data object structure:PDO_RX0 selection window

opens:

Here you can map the individual ports from the Port selection list into the receive PDO

"PDO_RX0" by clicking the >> button. With the Up and Down buttons, you can change the

order of the ports within the PDO.

In the following example, the ports "LPortControl1" and "Lport32In1" have been mapped

into the receive PDO "PDO_RX0" and the ports "LPortStatus1" and "LPort32Out1" have been

mapped into the transmit PDO "PDO_TX0":

Note

The port mapping is not a configuration, which can be carried out online for the Servo

Drive 9400 HighLine. For this purpose, the »Engineer« project must be updated and then

the application must be downloaded.