14 parameter reference, 4 table of attributes 112, Table of attributes – Lenze E94AYCPM User Manual

Page 112

Advertising
background image

14

Parameter reference

14.4

Table of attributes

112

Lenze · E94AYCPM communication module (PROFIBUS®) · Communication Manual · DMS 12.0 EN · 11/2012 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Table of attributes

Code

Name

Index

Data

Access

dec

hex

DS

DA

DT

Factor

R

W

CINH

C13850

All words to master

10725

29E5

A

32

UNSIGNED_16

1

;

C13851

All words from master

10724

29E4

A

32

UNSIGNED_16

1

;

C13852

All words to standard device

10723

29E3

A

32

UNSIGNED_16

1

;

C13853

All words from standard device

10722

29E2

A

32

UNSIGNED_16

1

;

C13860

Settings

10715

29DB

A

4

UNSIGNED_8

1

;

C13861

Bus status

10714

29DA

E

1

UNSIGNED_16

1

;

C13862

Bus counter

10713

29D9

A

4

UNSIGNED_16

1

;

C13863

Baud rate

10712

29D8

E

1

UNSIGNED_8

1

;

C13864

Active station address

10711

29D7

E

1

UNSIGNED_8

1

;

C13865

Display: Most recent PRM data

10710

29D6

E

1

OCTET_STRING

;

C13866

Display: Most recent CFG data

10709

29D5

E

1

OCTET_STRING

;

C13867

Display: Most recent diagnostic data

10708

29D4

E

1

OCTET_STRING

;

C13868

Display: DP state

10707

29D3

E

1

UNSIGNED_8

1

;

C13880

Reaction on communication fault

10695

29C7

A

2

UNSIGNED_8

1

;

;

C13881

Monitoring time: Data exchange

10694

29C6

E

1

UNSIGNED_16

1

;

;

C13882

Monitoring time: Watchdog

10693

29C5

A

2

UNSIGNED_32

1

;

C13885

Clear process data

10690

29C2

E

1

UNSIGNED_8

1

;

;

C13886

Set ext. diagnostic bit upon

10689

29C1

E

1

BITFIELD_8

;

;

C13887

Suppress signalling diag. mess. upon

10688

29C0

E

1

BITFIELD_8

;

;

C13897

PROFIsafe: Target address

10678

29B6

E

1

UNSIGNED_16

1

;

;

C13899

Station address

10676

29B4

E

1

UNSIGNED_8

1

;

;

C13900

Firmware product type

10675

29B3

E

1

VISIBLE_STRING

;

C13901

Firmware compilation date

10674

29B2

E

1

VISIBLE_STRING

;

C13902

Firmware version

10673

29B1

E

1

VISIBLE_STRING

;

C13920

Display: DIP switch setting

10655

299F

E

1

UNSIGNED_8

1

;

C14850

All words to master

9725

25FD

A

32

UNSIGNED_16

1

;

C14851

All words from master

9724

25FC

A

32

UNSIGNED_16

1

;

C14852

All words to standard device

9723

25FB

A

32

UNSIGNED_16

1

;

C14853

All words from standard device

9722

25FA

A

32

UNSIGNED_16

1

;

C14860

Settings

9715

25F3

A

4

UNSIGNED_8

1

;

C14861

Bus status

9714

25F2

E

1

UNSIGNED_16

1

;

C14862

Bus counter

9713

25F1

A

4

UNSIGNED_16

1

;

C14863

Baud rate

9712

25F0

E

1

UNSIGNED_8

1

;

C14864

Active station address

9711

25EF

E

1

UNSIGNED_8

1

;

C14865

Display: Most recent PRM data

9710

25EE

E

1

OCTET_STRING

;

C14866

Display: Most recent CFG data

9709

25ED

E

1

OCTET_STRING

;

C14867

Display: Most recent diagnostic data

9708

25EC

E

1

OCTET_STRING

;

C14868

Display: DP state

9707

25EB

E

1

UNSIGNED_8

1

;

C14880

Reaction on communication fault

9695

25DF

A

2

UNSIGNED_8

1

;

;

C14881

Monitoring time: Data exchange

9694

25DE

E

1

UNSIGNED_16

1

;

;

C14882

Monitoring time: Watchdog

9693

25DD

A

2

UNSIGNED_32

1

;

C14885

Clear process data

9690

25DA

E

1

UNSIGNED_8

1

;

;

C14886

Set ext. diagnostic bit upon

9689

25D9

E

1

BITFIELD_8

;

;

C14887

Suppress signalling diag. mess. upon

9688

25D8

E

1

BITFIELD_8

;

;

C14897

PROFIsafe: Target address

9678

25CE

E

1

UNSIGNED_16

1

;

;

C14899

Station address

9676

25CC

E

1

UNSIGNED_8

1

;

;

C14900

Firmware product type

9675

25CB

E

1

VISIBLE_STRING

;

C14901

Firmware compilation date

9674

25CA

E

1

VISIBLE_STRING

;

Advertising